Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1967 1
1969 1
1978 1
1980 1
1983 2
1985 1
1986 2
1988 1
1989 2
1991 2
1993 1
2001 1
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

16 results

Results by year

Filters applied: . Clear all
Page 1
Microphotometry in immunofluorescence.
Nairn RC, Herzog F, Ward HA, De Boer WG. Nairn RC, et al. Clin Exp Immunol. 1969 Jun;4(6):697-705. Clin Exp Immunol. 1969. PMID: 4891246 Free PMC article.
A specially sensitive version of the Reichert microphotometer provides a means of obtaining accurate measurements of the emission of immunofluorescent microscopical preparations. ...The photometer has permitted determinations of titre of antisera, assessment of the validit …
A specially sensitive version of the Reichert microphotometer provides a means of obtaining accurate measurements of the emission of …
Calibration of a flow cytometer against a microphotometer for morphologic cell identification.
Simmons DM, Dyson JE. Simmons DM, et al. Anal Quant Cytol Histol. 1988 Jun;10(3):181-8. Anal Quant Cytol Histol. 1988. PMID: 3165638
The calibration of a flow cytometer against a microphotometer, to allow the correlation of cell morphology with fluorescence intensity, is described. Using three human lymphoblastoid cell lines, the photomultiplier amplification of the microphotometer and the flow c …
The calibration of a flow cytometer against a microphotometer, to allow the correlation of cell morphology with fluorescence intensit …
An automatic microspectrophotometric scanning method for the measurement of bone formation rates in vivo.
Sontag W. Sontag W. Calcif Tissue Int. 1980;32(1):63-8. doi: 10.1007/BF02408522. Calcif Tissue Int. 1980. PMID: 6159059
After vital staining with calcein, the fluorescence of a bone section was measured with a microphotometer controlled by a mini computer. After staining the bone structure with alizarin red S in a second step, the section was measured in transmitted light. ...The advantages …
After vital staining with calcein, the fluorescence of a bone section was measured with a microphotometer controlled by a mini comput …
The intensity of the light reflex on retinal arteries and veins.
Brinchmann-Hansen O, Sandvik L. Brinchmann-Hansen O, et al. Acta Ophthalmol (Copenh). 1986 Oct;64(5):547-52. doi: 10.1111/j.1755-3768.1986.tb06971.x. Acta Ophthalmol (Copenh). 1986. PMID: 3811866
The intensity profiles of the central light streak on various sized retinal vessels were measured by a computerized high quality scanning microphotometer. From the fundus photographs in 40 young men 240 arteries and 240 veins were analysed, and light streaks were found on …
The intensity profiles of the central light streak on various sized retinal vessels were measured by a computerized high quality scanning …
Comparison of antifading agents used in immunofluorescence.
Krenik KD, Kephart GM, Offord KP, Dunnette SL, Gleich GJ. Krenik KD, et al. J Immunol Methods. 1989 Feb 8;117(1):91-7. doi: 10.1016/0022-1759(89)90122-1. J Immunol Methods. 1989. PMID: 2464041
Immunofluorescence fading and intensity were measured quantitatively using the Zeiss Zonax microphotometer system. All of these agents effectively retarded fluorescence fading; p-phenylenediamine and n-propyl gallate were the most effective. ...
Immunofluorescence fading and intensity were measured quantitatively using the Zeiss Zonax microphotometer system. All of these agent …
Double labeling and in vitro versus in vivo incorporation of bromodeoxyuridine in patients with acute nonlymphocytic leukemia.
Raza A, Ucar K, Preisler HD. Raza A, et al. Cytometry. 1985 Nov;6(6):633-40. doi: 10.1002/cyto.990060620. Cytometry. 1985. PMID: 3905302 Free article.
The percentage of S-phase cells obtained by each method was compared in 50 samples, and the correlation coefficient was r = 0.89. ...Results showed only black grains overlying the nuclei of fluorescent cells in each group. An automated microphotometer was used to qu …
The percentage of S-phase cells obtained by each method was compared in 50 samples, and the correlation coefficient was r = 0.89. ... …
Sexually dimorphic, androgen sensitive, enkephalinergic afferents to a lumbar motor nucleus of rats.
Coquelin A, Micevych PE, Arnold AP. Coquelin A, et al. J Neurobiol. 1991 Nov;22(8):873-81. doi: 10.1002/neu.480220808. J Neurobiol. 1991. PMID: 1779226
The sections were incubated with primary antiserum raised against methionine enkephalin and bound antibodies were visualized using the avidin-biotin-peroxidase technique. A microphotometer was used to compare the staining density in laminae I-II of the dorsal horn, ventral …
The sections were incubated with primary antiserum raised against methionine enkephalin and bound antibodies were visualized using the avidi …
A computer method for the automatic reduction of spectroscopic data.
Ditzel EF, Giddings LE Jr. Ditzel EF, et al. Appl Opt. 1967 Dec 1;6(12):2085-90. doi: 10.1364/AO.6.002085. Appl Opt. 1967. PMID: 20062364
A computer program, written in Fortran IV and for use with an associated spectral comparator, has been developed at The Naval Research Laboratory for the purpose of automatically reducing spectroscopic data. A Datex digitalizing magnetic tape recorder in conjunction with a …
A computer program, written in Fortran IV and for use with an associated spectral comparator, has been developed at The Naval Researc …
Histometric features for the grading of prostatic carcinoma.
Bibbo M, Kim DH, Pfeifer T, Dytch HE, Galera-Davidson H, Bartels PH. Bibbo M, et al. Anal Quant Cytol Histol. 1991 Feb;13(1):61-8. Anal Quant Cytol Histol. 1991. PMID: 2025375
Tissue sections from the selected cases were stained by the Feulgen method and digitized by a video-based microphotometer. Twenty total fields were recorded for each grade: ten at high resolution (an image sampling of 0.5 micron per pixel) and ten at low resolution (0.8 mi …
Tissue sections from the selected cases were stained by the Feulgen method and digitized by a video-based microphotometer. Twenty tot …
The action spectrum for chloroplast movements and evidence for blue-light-photoreceptor cycling in the alga Vaucheria.
Blatt MR. Blatt MR. Planta. 1983 Nov;159(3):267-76. doi: 10.1007/BF00397535. Planta. 1983. PMID: 24258178
Light-induced aggregation of chloroplasts was examined at eight wavelengths of light between 385 and 528 nm. A fiber-optic microphotometer was employed and the response was quantitated on the basis of the rate of 675-nm transmittance change after correcting for changes in …
Light-induced aggregation of chloroplasts was examined at eight wavelengths of light between 385 and 528 nm. A fiber-optic microphotomete
16 results